Turkish Journal of Nephrology
Case Report

Removal of Broken Hemodialysis Catheter from Subclavian Vein via Snare Under Fluoroscopy

1.

Dicle University Faculty of Medicine, Department of Cardiovascular Surgery, Diyarbakır, Turkey

Turkish J Nephrol 2014; 23: 73-76
DOI: 10.5262/tndt.2014.1001.16
Read: 1445 Downloads: 810 Published: 07 February 2019

Venous access with a central catheter is typically a necessary technique for hemodialysis. Although, central venous catheters are widely used, they may cause life-threatening complications by migration of fractured catheter pieces. Thus, venous catheters should be controlled routinely by medical staff or the patients themselves. In this paper we report a case of a fractured catheter with vena cava migration in which there were no symptoms and describe the non-surgical retrieval of the migrated catheter by snare technique.